jayright.blogg.se

Ladder jack scaffold fall protection
Ladder jack scaffold fall protection







ladder jack scaffold fall protection

No violation: Pump jack pole is secured to mudsill of 3/4 inch plywood which is staked into the ground.ġ926.452(j)(2): Poles shall be secured at the top by rigid triangular bracing or equivalent.ġ926.452(j)(3): When work benches are used for fall protection, they must meet requirements of 1926.451(g): No violation: No midrail is needed because gap between platforms is 23 inches. No violation: The top is secured by metal bracing.ġ926.452(j)(2): Pumpjack poles shall be secured to the structure at the bottom by the rigid triangular bracing or equivalent. No violation: Ladder was secured to pump jack brackets and poles giving required strength.ġ926.452(j)(2): Pumpjack poles shall be secured to the structure at the top by the use of rigid triangular bracing or equivalent. Violation: Ends are not guarded on this narrow scaffold.ġ926.451(g)(4)(iv): When midrails are used, they shall be installed between the top edge of the guardrail system and the platform surface.ġ926.451(g)(4)(ix): Midrails shall have 150 lbs. No violation: Ladder arranged so that worker can step onto scaffold directly from the ladder.ġ926.451(g)(1): Guardrails are required at all open sides and ends of scaffolds. Violation: Soil is undercutting beneath the plywood because it was not compacted and protected from water.ġ926.451(c)(4)(i): Footing shall be level, sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.ġ926.451(e)(1): Safe access shall be provided to scaffolds. Violation: Use of another scaffold as a footing can cause displacement by allowing scaffold planks to shift out from under the left leg resulting in its collapse.ġ926.451(c)(2)(i): Footing shall be sound, rigid, and capable of supporting the loaded scaffold without settling or displacement.

ladder jack scaffold fall protection

Siding contractor putting a wood pump jack leg onto a welded frame scaffold. Violation: The right platform is not 6 inches over the pump jack bracket.ġ926.451(c)(2)(i): Footing shall be capable of preventing displacement. PUMP JACK/LADDER JACK SCAFFOLDPHOTO COMPLIANCE GUIDEĪurora Area Office 1997 Scaffold of the YearJudged the Worst Scaffold of the Year By Our Compliance Staff 20' high - No Guardrails Expanded view of scaffold leg footing.ġ926.451(b)(4): Each scaffold platform shall extend over its end support at least 6 inches.









Ladder jack scaffold fall protection